最後更新: 2024-04-23
目錄
iDRAC Default Login
Default Login: root / calvin
Basic Setting
1 設置用 Java console Client
好處: 有獨立的 window
P.S.
用 javaws.exe(C:\Program Files\Java\jre6\bin\javaws.exe) 開啟下載的 java file(viewer.jnlp)
# Console
2. 用虛擬 CD-ROM Boot 機
3. security 設定
NAT (Firewall Port)
Using the Virtual Media function on iDRAC
- 623 # RMCP/RMCP+
- 3668, 3669 # Virtual Media Service
- 3770, 3771 # Virtual Media Secure Service
- 5900 # Console Redirection keyboard/mouse
Cmd tools Usage
https://datahunter.org/racadm
Host Header check
The webserver in iDRAC9 firmware version 5.10.00.00 enforces an HTTP / HTTPS Host Header check by default.
'400 - Bad Request' errors when the specified FQDN does not match the iDRAC 'DNSRacName' or 'DNSDomainName' values.
# Disable host header check
racadm set idrac.webserver.HostHeaderCheck 0
# Add manual entry to allow list
racadm set idrac.webserver.ManualDNSEntry 192.168.20.30
racadm set idrac.webserver.ManualDNSentry 192.168.20.30,idrac.mydomain.com
E-Mail Alert
V9
# 什麼情況會出 Alerts, 用 "Quick Alert Configuration" 可以快速選到想出 Alert 的項目
# 收件者及 SMTP Server Settings(host, pot)
Configuration menu > System Settings > "Alert Configuration" Section
# 設定 hostname
V8
V7
# E-mail from default 係 idrac-SN@IP, 所以必須更新
# Set 什麼出 Alert 及 Set SMTP host, port
Reboot iDRAC system
* 在所有情況下, 只有 iDRAC 會重新開機, 不會重新開機伺服器
# 重新開機 iDRAC 而不變更任何 iDRAC 組態設定
racadm racreset
先會 ping 唔到, 之後再 ping 返.
P.S.
# reset the to defaults
racadm racresetcfg
Upgrade iDRAC Firmware
V9
1. Upload firmware exe file in iDRAC
Maintenance > System Update > Manual Update
2. 選擇你 upload 的 firmware 之後再 click install
V7
DRAC > Update and Rollback
* 將 BIOS 的 exe 在 iDRAC 直接 upload 上去
Reboot 後會自動進入 Lifecycle controller 升級
V6
1) Download Firmware
去 https://www.dell.com/support/ 下載 Firmware
類別: 內嵌式伺服器管理
解壓: ESM_Firmware_KPCCC_WN32_2.92_A00.exe 後獲得 firmimg.d6
升級
iDRAC Settings -> Update