Card
- KX-NS5180X 6-Ports Analogue Trunk Card with Caller ID. (LCOT6)
- KX-NS5172X 16-Port Digital line Card (DLC16)
Port / Card
On / Off
- OUS = Out of service
- INS = In Service
Backup to NAS
Login Web Panel
[1] Connect NAS
Home icon: Network Service > Other > NAS
* Mount directory 直接用 Folder 名就得, 不用加 "/" 或 "\"
[2] Backup
Maintenance icon: Tool > 1.System Data Backup > 2. Backup To NAS
* 主要都係 backup 左 DFSYS 這檔案
Reboot
Maintenance icon > System Control > 3.System Reset > Backup
* 必須 Backup, 否則會無晒 D Setting !!
Debug Log
Maintenance icon > Utility > 3.Log > 2. SysLog
Msg
MN ALM #232 00 10501 MPR-LPR communication error
Level
ie. "MN ALM"
Major Alarm (MJ ALM):
Errors that affect the whole system operation, or result in system failure
Minor Alarm (MN ALM):
Errors that affect certain part of system operation
Error Code: Three-digit error code
ie. "#232"
Sub Code: Five-digit sub code (1XXYY)
ie. "10501"
- 1: Cabinet number (在 NS700 只會是 1)
- XX: Slot number
- YY: Physical port number (01 to 16)
Notes
Slot:
KX-TDA100: 00 to 06 (00: MPR slot; 01 to 05: Free slot; 06: Option slot)
When there is no parameter for slot and physical port number, XX and YY will be displayed as "00".
Example: Sub code for MPR card = 10000